Welcome back. The previous lesson separated a completed daily PM report from a rolling average, a NowCast, and a forecast. Once you know which concentration and time period a report represents, the next step is to understand how that concentration becomes an AQI number.
This lesson uses the 2024 U.S. PM2.5 breakpoints. You will locate the right concentration interval, calculate a PM2.5-specific index by interpolation, and apply the table’s precision rules. That gives you a way to check a reported number without treating every difference between services as suspicious.
A breakpoint table is a conversion rule
A PM2.5 concentration is a measurement expressed in micrograms per cubic meter, or . A PM2.5-specific AQI is a number calculated from an appropriate PM2.5 concentration. The two are not interchangeable: a concentration of does not mean an AQI of 18.7.
A breakpoint table pairs ranges of concentrations with ranges of index values. Use the EPA’s 2024 table below as the dated rule for this lesson.
Final Updates to the Air Quality Index (AQI) for Particulate ...
Read the EPA fact sheet to identify which column supplies the 2024 PM2.5 concentration breakpoints. The adjacent column gives previous breakpoints, not alternative values to use in the same calculation.
On PDF page 2, find the table headed “2024 AQI for Fine Particle Pollution.” Read the table rows from Good through Very Unhealthy, matching each AQI index range to the Updated AQI Category Breakpoints column. Stop before the Hazardous row. Immediately below the table, read the column explanation to confirm how the previous and updated columns differ.
For calculations in the bounded ranges, the relevant entries are:
| 2024 U.S. PM2.5 category | PM2.5 concentration | AQI values |
|---|---|---|
| Good | 0.0–9.0 | 0–50 |
| Moderate | 9.1–35.4 | 51–100 |
| Unhealthy for Sensitive Groups | 35.5–55.4 | 101–150 |
| Unhealthy | 55.5–125.4 | 151–200 |
| Very Unhealthy | 125.5–225.4 | 201–300 |
The table specifies both ends of each interval. For example, a prepared concentration of lies between 9.1 and 35.4, so its index lies between 51 and 100. The table alone does not say exactly where between 51 and 100; that is what interpolation calculates.
This is a dated, pollutant-specific table. Its PM2.5 concentration breakpoints should not be used for PM10 or another pollutant. Likewise, selecting the “previous” column in the fact sheet would change the rule being applied. You will compare versions more closely in a later lesson; for now, keep one stated version throughout a calculation.
Interpolation: finding your place within an interval
Within a pair of breakpoints, the AQI calculation treats the relationship between concentration and index as a straight line. The diagram shows one such interval. Its lower endpoint pairs concentration with index ; its upper endpoint pairs with . A concentration partway across the interval receives an index the same fraction of the way up its AQI range.

Written as a calculation, that idea is:
Here is the prepared concentration for pollutant ; and are the concentration breakpoints enclosing it; and and are their corresponding AQI values. In plain terms, the fraction tells you how far the concentration has moved across its interval. The formula applies that same fraction to the interval’s AQI range.
The line is straight within the selected interval, not necessarily across the entire AQI scale. Always select the row first, then use that row’s four endpoints.
Precision is part of the method
Before selecting a row, you need to know what the reporting rule does with extra decimal places. The EPA technical document sets out the sequence: truncate the concentration to the specified precision, select breakpoints, calculate the index, then round the index to the nearest integer. Truncating and rounding are different operations.
Technical Assistance Document for the Reporting of Daily Air Quality
Read the AirNow technical document for the calculation procedure and its pollutant-specific concentration precision rules. Focus on the order of operations rather than on choosing the highest value among monitors, which is a separate reporting decision.
On printed page 13, in Section IV, “CALCULATING THE AQI,” find “Calculating the AQI from pollutant concentration data.” Read the numbered procedure, starting at item 1 and stopping at item 4. Note particularly that PM2.5 is truncated to one decimal place, whereas PM10 is truncated to an integer. Then read the definitions immediately below Equation 1, from the variable definitions. Stop before Table 6 on the next page.
For positive PM2.5 concentrations, truncating to one decimal place means dropping later digits, not increasing the tenths digit. Thus becomes , not . Only after interpolation do you round the calculated AQI to a whole number. Do not round an intermediate result merely to make the arithmetic tidier.
The precision rule also determines which row contains a value near a boundary. A raw PM2.5 concentration of , for example, truncates to . Under the 2024 table, is the upper Good breakpoint and corresponds to AQI 50. Rounding the concentration to instead would incorrectly move it to the Moderate row, whose lower endpoint is AQI 51.
A complete PM2.5 calculation
Suppose a suitable PM2.5 concentration for the report’s stated averaging period is . Using the 2024 U.S. PM2.5 table, proceed in order:
- Prepare the concentration. Truncate to one decimal place, giving .
- Select the interval. lies in 9.1–35.4, the Moderate row. Its corresponding AQI endpoints are 51 and 100.
- Interpolate, then round the index.
The PM2.5-specific AQI is 69 after rounding to the nearest integer. The result is Moderate, consistent with the row chosen at the start. That category check is useful: if the calculation had produced an index outside 51–100, the selected endpoints or arithmetic would need another look.
There is an important input check before any of these steps. A breakpoint table converts a concentration prepared for the reporting method; it does not make an arbitrary latest-hour reading equivalent to a completed 24-hour PM2.5 average. For a current U.S. PM NowCast, the recent observations are processed into a NowCast concentration before AQI conversion. For a completed daily PM report, the relevant concentration represents its completed 24-hour period. Confirm the pollutant, unit, time basis, table version, and precision rule before comparing your result with a service’s number.
Key takeaways
A pollutant-specific AQI is calculated from a concentration using that pollutant’s breakpoint table. For the 2024 U.S. PM2.5 example, you first truncated the concentration to one decimal place, found its enclosing concentration and AQI endpoints, interpolated within that interval, and rounded the resulting index to a whole number. Keeping the table date, averaging period, and order of precision steps visible makes the calculation reproducible.
This result is a PM2.5-specific index, not automatically the overall AQI. The next lesson will consider how a reporting system combines separately calculated pollutant indices into the overall value it displays.