Welcome. This course begins with the measurements beneath an air-quality report. Before comparing index numbers from two services, it helps to know what a particulate-matter reading actually says—and what it does not. In this lesson, you will interpret the size cutoff in PM2.5 and PM10 and the mass-per-volume unit used to report their concentrations.


The number in the name is a size cutoff

Particulate matter, or PM, is a mixture of tiny solid particles and liquid droplets suspended in air. The number attached to PM describes a particle-size category, measured in micrometres (). One micrometre is one-millionth of a metre.

PM2.5 refers to particles with an aerodynamic diameter of approximately or less. PM10 refers to particles with an aerodynamic diameter of approximately or less. Aerodynamic diameter describes how a particle behaves while moving through air, rather than simply measuring its width under a microscope. The cutoffs are used to sort particles for measurement; real instruments do not separate every particle at a perfectly sharp boundary.

Watch the brief definition in Smart Air’s 5 Things You Should Know about PM2.5 Air Pollution. Focus on “or below”: PM2.5 does not mean that every particle is exactly across.

5 Things You Should Know about PM2.5 Air Pollution

Smart Air’s 5 Things You Should Know about PM2.5 Air Pollution provides a quick visual introduction to the size cutoff.

Watch the definition. Note the distinction between a maximum size and a single particle size.

The comparison below gives those dimensions some scale. It is a schematic, not a photograph of particles that can be counted or identified by colour.

Schematic comparison of PM2.5 and PM10 size cutoffs with a human hair and fine beach sand; the labels also give examples of materials found in each size range.

The two categories overlap. PM2.5 is the fine portion within PM10; particles larger than but within the PM10 category make up its coarser portion. Thus, “PM10” does not mean “only particles between and .”

For a more precise account of that relationship, read the indicated passage in the archived Canadian assessment report. Its terminology is more technical than you need to memorise; concentrate on which fraction contains which particles.

ARCHIVED - Priority Substances List Assessment Report for Respirable Particulate Matter - Canada.ca

The archived Canadian assessment report distinguishes the fine fraction from the coarser fraction within PM10.

In “2.0 Summary of Information Critical to Assessment of ‘Toxic’ Under CEPA 1999,” go to “2.1 Identity and physical/chemical properties,” then “2.1.1 Identity.” Start at the sentence beginning “PM10 is generally subdivided into a fine fraction.” Read the fraction definitions through the discussion of primary and secondary particles. Focus on why PM2.5 is included in PM10 rather than being a separate, nonoverlapping category.



A size category is not a chemical identity

The size label tells you which particles are included, not what those particles are made of. A PM2.5 reading might include material associated with combustion as well as particles formed in the air from gases. The coarser portion of PM10 can include windblown dust, sea spray, or pollen. These are examples of sources, not rules that identify the origin of a particular reading.

Read the World Health Organization’s short explanation to connect particle size with this variety of materials.

Air quality, energy and health

The World Health Organization’s Air quality, energy and health page describes particulate matter as a mixture and gives examples of fine and coarse particle sources.

Under “Particulate Matter,” read the definition. Then continue from the sentence beginning “Sources of the largest particles called coarse particles” through the source examples. Focus on the distinction between a size-based measurement and an identification of chemical composition.

This distinction matters when interpreting a report. “PM2.5 is ” identifies the size fraction and its measured mass concentration. It does not, on its own, establish whether the particles came from traffic, smoke, cooking, or another source.



The reported unit is mass per volume of air

A particulate-matter concentration is commonly expressed in micrograms per cubic metre, written . A microgram () is one-millionth of a gram; a cubic metre () is a volume of air. Crucially, and are different units: the first describes size, while the second describes mass.

The basic measurement idea is to collect particles from a known volume of air and divide their collected mass by that volume:

The Canadian assessment report describes a direct method: air passes through a size-selective inlet, particles collect on a pre-weighed filter, and the filter’s gain in mass is divided by the sampled air volume. Read its account to make the unit concrete; the lesson does not require you to learn the different instrument designs.

ARCHIVED - Priority Substances List Assessment Report for Respirable Particulate Matter - Canada.ca

The report’s monitoring section shows how a collected particle mass becomes a concentration per volume of air.

In “2.3 Exposure characterization,” go to “2.3.1 Monitoring technology.” In its opening paragraph, read from the description of direct filter measurements through the size-separated sampling explanation. Follow the roles of the filter’s mass gain, the volume of air sampled, and the inlet that selects a particle-size fraction.

Suppose a PM2.5 sampler draws of air and collects of particles in that size fraction. Its measured concentration is

In plain language, that is 16 micrograms of PM2.5 particle mass per cubic metre of sampled air. It is not 16 particles, a particle diameter of 16, or an air-quality index of 16. Nor does it imply that every individual cubic metre contained exactly that amount: a reported concentration summarises the air sampled over a measurement period.



Reading PM2.5 and PM10 together

Imagine a report from the same place and measurement period showing PM2.5: and PM10: . The first value is the mass concentration of the fine fraction. The second includes that fine fraction and the coarser particles counted as PM10. Under those matched conditions, their difference——estimates the mass concentration of the coarser fraction.

That subtraction is meaningful only when the readings represent comparable sampling periods and locations. If one figure comes from a different hour or monitoring site, the difference no longer cleanly describes a particle-size fraction. Measurements also have uncertainty, so the expected nesting of PM2.5 within PM10 need not appear perfectly in every pair of reported values.

Finally, a concentration is not an AQI number. The concentration reports particle mass per air volume; an index is a separate way of translating pollutant measurements into a reporting scale. A concentration also needs its measurement period for full interpretation: the unit alone does not tell you whether the value represents an hour, a day, or another interval.



Key takeaways

PM2.5 and PM10 name size-selected, overlapping particle categories. A reading in reports the mass of particles in that category per volume of sampled air, not a particle count or an index value. PM10 includes the fine PM2.5 fraction as well as a coarser fraction, while neither label identifies the particles’ chemical source.

The next lesson builds on this distinction by separating pollutant concentrations from pollutant-specific index values and an overall air-quality index.