Skip to main content

Welcome to a Grasp lesson

Create a free account to keep studying and create your own study path.

Lesson 31

Ionic Basis of SA Node Automaticity

This lesson is built with resources from aerjournal.com and cvphysiology.com.

Hello! Welcome back to our study of cardiac electrophysiology.

In our last lesson, we established the fundamental differences between the "fast response" action potentials of ventricular myocytes and the "slow response" action potentials of the heart's pacemaker cells. We saw that pacemaker cells, like those in the sinoatrial (SA) node, lack a stable resting potential and instead exhibit a slow, spontaneous depolarization. This unique property, known as automaticity, is what allows the heart to generate its own rhythm.

Today, we will take a deep dive into the very mechanism that drives this rhythm. Our learning outcome is to explain the ionic basis of automaticity in sinoatrial (SA) node cells. We will move beyond simply identifying the pacemaker potential and dissect the intricate interplay of ion channels and currents that create it. This is a cornerstone concept for understanding both normal heart rhythm and the mechanisms of many arrhythmias.


The Pacemaker Potential: A Symphony of Currents

As we reviewed, the key feature of SA node cells is their unstable Phase 4, also known as the pacemaker potential or diastolic depolarization. This is the slow, upward drift in membrane potential from its most negative point (about -60 mV) up to the threshold for firing an action potential (about -40 mV).

This is not the result of a single ion current. Instead, automaticity arises from a beautifully coordinated sequence of changes in the permeability of the cell membrane to different ions.

To begin, let's get an overview of the key players involved.

Sinoatrial Node Action Potentials

The resource 'Sinoatrial Node Action Potentials' from CVPhysiology.com provides a concise and clear breakdown of the ion channels responsible for the different phases of the SA nodal action potential. Focus on the detailed description of Phase 4.

Please read the entire text, but pay special attention to the section titled 'Ion channels'. As you read about Phase 4, make a mental list of the three main ionic events that contribute to the spontaneous depolarization.

From your reading, you've seen that the pacemaker potential is driven by:

  1. An inward Na⁺ current known as the "funny" current (If).
  2. An inward Ca²⁺ current through T-type Ca²⁺ channels.
  3. A progressive decrease in an outward K⁺ current.

To build a more sophisticated and memorable model, physiologists often group these events into two interacting systems: the "Membrane Clock" and the "Ca²⁺ Clock". Let's explore each in turn.



1. The Membrane Clock: Surface-Level Timekeeping

The "Membrane Clock" refers to the time- and voltage-dependent ion channels embedded in the cell's surface membrane (the sarcolemma). These channels are the primary drivers of the early part of the pacemaker potential.

Biology of the Sinus Node and its Disease | AER Journal

This article from the AER Journal, 'Biology of the Sinus Node and its Disease', introduces the powerful concepts of the Membrane and Ca²⁺ clocks. We'll start with the Membrane Clock.

Please read the section titled 'The Membrane Clock'. This section details the three key membrane currents that contribute to early diastolic depolarization.

Let's break down the components of the Membrane Clock:

  • The Funny Current (If): This is the star of the show. It's a mixed Na⁺ and K⁺ inward current that flows through HCN channels (Hyperpolarization-activated Cyclic Nucleotide-gated channels). The most crucial and unique property of these channels is that they are opened by hyperpolarization. When the cell repolarizes to its most negative potential (~ -60 mV) at the end of Phase 3, these channels open, allowing a slow, steady influx of positive Na⁺ ions that begins the upward drift of the membrane potential.

  • Decay of the K⁺ Current (IK): During Phase 3 (repolarization), voltage-gated K⁺ channels are open, allowing K⁺ to rush out of the cell. As Phase 4 begins, these channels begin to deactivate. This reduces the outward, repolarizing K⁺ current. Think of it as easing off the brakes—reducing the outward flow of positive charge allows the inward If current to have a greater depolarizing effect.

  • Absence of the Inward Rectifier K⁺ Current (IK1): This is a critical point of contrast with ventricular myocytes. Myocytes have a strong IK1 current that is active at negative potentials, effectively clamping their membrane potential at a stable -90 mV. SA node cells lack IK1. This absence makes their membrane potential "labile" or unstable, allowing it to be influenced by the relatively weak If and to drift upwards.

Together, these three components of the Membrane Clock initiate the spontaneous depolarization at the start of Phase 4.



2. The Ca²⁺ Clock: Intracellular Reinforcement

While the Membrane Clock gets things started, another mechanism—the Ca²⁺ Clock—joins in to provide a final push to reach the action potential threshold. This clock involves intracellular Ca²⁺ handling by the sarcoplasmic reticulum (SR).

Biology of the Sinus Node and its Disease | AER Journal

Now, let's look at the second major contributor to automaticity, as described in the same AER Journal article.

Please read the section titled 'The Ca²⁺ Clock'. Focus on how spontaneous Ca²⁺ release from the SR ultimately leads to a depolarizing current at the cell membrane.

The Ca²⁺ Clock works through a clever multi-step process:

  1. Spontaneous Ca²⁺ Release: During mid-to-late Phase 4, the SR within the SA node cell spontaneously releases small, localized bursts of Ca²⁺ called "Ca²⁺ sparks" through its ryanodine receptors (RyRs).

  2. Activation of the Na⁺-Ca²⁺ Exchanger (NCX): These Ca²⁺ sparks increase the concentration of Ca²⁺ near the cell membrane. This activates the Na⁺-Ca²⁺ exchanger (NCX).

  3. Depolarizing Current: The NCX operates by extruding one Ca²⁺ ion from the cell in exchange for bringing three Na⁺ ions into the cell. This exchange is electrogenic—it results in a net inward movement of one positive charge. This inward Na⁺ current provides an additional depolarizing push that accelerates the final part of the pacemaker potential, helping it reach the -40 mV threshold.

The Membrane and Ca²⁺ clocks are mutually entrained, meaning they influence each other to create a robust and reliable rhythm generator. The initial depolarization from the Membrane Clock can enhance the Ca²⁺ release, and the subsequent activation of the Ca²⁺ Clock helps drive the membrane potential to threshold more quickly.


Putting It All Together: The Full Picture

Let's visualize the entire sequence of events during the pacemaker potential. The diagram below annotates an SA node action potential with the key currents.

Pacemaker Action Potential and Ionic Basis of Automaticity
This diagram illustrates the pacemaker action potential. Phase 4, the pacemaker potential, is driven by I<sub>f</sub>, T-type and L-type Ca²⁺ currents, and the decay of I<sub>K</sub>. Notice how multiple currents contribute to the upward slope before the main upstroke (Phase 0), which is caused by a large influx through L-type Ca²⁺ channels.

Here is a step-by-step summary of the ionic basis of automaticity:

  1. Start of Phase 4 (~ -60 mV): Repolarization from the previous action potential hyperpolarizes the membrane, activating the If current (inward Na⁺). Simultaneously, the repolarizing K⁺ currents begin to decay (decreasing outward K⁺). These "Membrane Clock" events start the slow depolarization.
  2. Mid-Phase 4 (~ -50 mV): As the membrane potential drifts upwards, transient T-type Ca²⁺ channels open, contributing a small inward Ca²⁺ current.
  3. Late Phase 4: The Ca²⁺ Clock engages. Spontaneous Ca²⁺ release from the SR activates the NCX, which brings in Na⁺, creating a net inward current that provides the final push toward threshold.
  4. Threshold (~ -40 mV): The membrane potential reaches the threshold for opening long-lasting L-type Ca²⁺ channels. The large influx of Ca²⁺ through these channels generates the rapid upstroke of Phase 0.
  5. Phase 3: The L-type Ca²⁺ channels inactivate, and voltage-gated K⁺ channels open, causing a K⁺ efflux that repolarizes the cell back to -60 mV, at which point the cycle begins again.
Test your understanding!

A drug called Ivabradine specifically blocks the HCN channels responsible for the If current. Based on your understanding of the pacemaker potential, what effect would this drug have on the heart rate, and why?

Show answer

Ivabradine would decrease the heart rate. By blocking the If current, it reduces the initial rate of spontaneous depolarization during Phase 4. This means it takes longer for the membrane potential to drift from -60 mV up to the threshold of -40 mV. A longer Phase 4 means fewer action potentials can be generated per minute, resulting in a slower heart rate (negative chronotropy).



Conclusion

Today, we've unpacked the intricate mechanism of cardiac automaticity. We learned that it's not a simple process but a sophisticated collaboration between two "clocks" that ensures the heart's reliable rhythm.

Key Takeaways:

  • Automaticity is driven by the pacemaker potential (Phase 4), a slow, spontaneous depolarization in SA node cells.
  • This potential is a result of the interplay between multiple ionic currents, not a single one.
  • The Membrane Clock initiates depolarization via the hyperpolarization-activated If current and the decay of outward K⁺ currents. The lack of an IK1 current is essential for this drift.
  • The Ca²⁺ Clock contributes to late depolarization via SR Ca²⁺ release and activation of the electrogenic Na⁺-Ca²⁺ exchanger (NCX).
  • This dual-system provides a robust, reliable mechanism for generating the heartbeat.

Preview of the Next Lesson:

Now that we have a deep understanding of how the pacemaker impulse is generated in the SA node, the next logical question is: how does this electrical signal spread throughout the rest of the heart to coordinate a unified contraction? In our next lesson, we will describe the cardiac conduction system and the sequence of electrical activation of the heart.